Introduction for fluoroplastic lined full port ball valve
Product advantages:
1. Corrosion resistance: The wide internalcavity and the sphere are lined with 2.5~3mm thick F46 or PFA, which can resistacid, alkali and strong corrosion.
2. Adopt soft sealing valve seat, goodsealing performance.
3. Small size, light weight, simplestructure, convenient installation and maintenance.
4. Small flow resistance and largecirculation capacity.
5. If equipped with a valve positioner,proportional adjustment can be achieved.
6. The valve can be equipped with varioustypes of electric actuators, and it is matched with ZDRF-16C type electricfluorine lining plastic type O type ball valve.
Main parts materials :table 1
Valve type |
Straight-through two-piece cast ball valve |
DN |
15,20, 25, 32,40,50,65,80,100,125,150, 200mm |
PN |
1.0,1.6,2.0Mpa |
End type |
RF Flange |
End flange fastener |
GB6170 (Hexagon nut), GB5782 (Hexagon head bolt) or GB901 (Equal length double-headed stud) |
Body material |
ZG230-450,CF8,CF8M,CF3M lined with F46 or PFA |
Temperature |
FF46:-30°C~+120°C PFA:-30°C~+150°C |
Packing box |
WCB,CF8,CF8M,CF3M lined with F46 or PFA |
Packing seal ring |
V-shaped polytetrafluoroethylene (PTFE) |
Valve core type |
Cylindrical through hole with rod sphere |
Ball material |
ZG230-450,CF8,CF8M,CF3M lined with F46 or PFA |
Rated stroke |
90°C |
Flow characteristics |
Quick opening, approximately equal percentage after locator |
Supporting actuator parameter table: Table2
Model
Item |
Cylinder piston actuator |
Electrical actuator |
Electrical actuator |
|
Single acting |
Double acting |
3610 |
3614 |
|
Spring return |
Non-Spring return |
AC reversible motor resolution 0.4% |
AC reversible motor |
|
Function |
On-off, regulate with positioner |
control |
On-off |
|
Supply pressure Supply voltage input signal |
Air supply pressure according to ball valve torque(0.4~0.6Mpa), max air supply pressure :1.0Mpa, |
Supply voltage:220V,50/60HZ Input signal:4~20mA.DC |
Supply voltage:220V,50/60HZ Input signal: forward & reverse switching contacts |
|
Interface |
Female thread G1/4 or electrical interface of positioner female thread G1/2 |
Normal A,B,C type 2-PF1/2 Normal D type and explosion-proof 2-PF3/4 |
Normal A,B,C type 2-PF1/2 Normal D type and explosion-proof 2-PF3/4 |
|
Forward |
Operating increase pressure to open |
Input electrical signal to close |
On, off, stop |
|
Reverse |
Operating increase pressure to close |
Input electrical signal to open |
||
Ambient temperature |
-40°C~+70°C |
Normal without heater:-10~+60°C Normal with heater:-35~+60°C Explosion-proof:-10~+60°C |
Normal without heater:-10~+60°C Normal with heater:-35~+60°C Explosion-proof:-10~+60°C |
|
Optional accessories |
Solenoid valve, limit switch, positioner, hand wheel etc |
Overload protection unit(C,D type required), Torque switch, Space heater(no required for explosion-proof),hand operate device |
Overload protection unit(C,D type required), Torque switch, Space heater(no required for explosion-proof),hand operate device |
Notes:1.vave and actuator model number:ZDRF
2.Electricalactuator can be selected by client
Standard pneumatic actuator andspecifications: table 3
DN(mm) |
15 |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
|
|||||||||||||
Actuator |
Single acting |
Model |
SR75 |
SR83 |
SR92 |
SR105 |
SR125 |
SR140 |
SR160 |
SR190 |
SR210 |
SR270 |
|
|||||||||||||
Torque (Nm) |
90° |
23.2 |
36.8 |
55 |
88.6 |
125.4 |
206.3 |
333 |
469 |
575 |
1192 |
|
||||||||||||||
0° |
16.9 |
25.3 |
37.3 |
56.9 |
83.8 |
137.3 |
223 |
303 |
417 |
848 |
|
|||||||||||||||
Double acting |
Model |
DA63 |
DA75 |
DA83 |
DA92 |
DA105 |
DA125 |
DA140 |
DA160 |
DA190 |
DA240 |
|
||||||||||||||
Torque(Nm) |
28.4 |
40.3 |
61.6 |
90.5 |
205 |
205 |
351 |
535 |
861 |
1546 |
|
|||||||||||||||
Actuator type |
Pneumatic actuator on/off ,electrical actuator on/off |
|
||||||||||||||||||||||||
Seat leakage |
GB/T4213-92VI,less than rated Kv value 10-7 ANSI B16.104-81vi, less than rated Cv value 10-7 |
|
||||||||||||||||||||||||
pressure difference |
Within PN range |
|
||||||||||||||||||||||||
Rated travel |
90° |
|
||||||||||||||||||||||||
Rated flow KV |
17 |
33 |
62 |
95 |
146 |
232 |
350 |
439 |
810 |
1205 |
1912 |
3014 |
||||||||||||||
Air supply(Mpa) |
0.5 |
|
||||||||||||||||||||||||
Notes:1.Ball valve pressure difference baseon different actuator, different output torque lead to different pressuredifference. Larger actuator output torque larger allowable pressure different, viceversa.
Main performance specifications table4
Item |
PN1.0 |
PN1.6 |
Shell test |
1.5(Mpa) |
2.4(Mpa) |
Seal test (Hydraulic) |
1.1(Mpa) |
1.8(Mpa) |
Leakage(Air) |
0.6(Mpa) |
Dimensions:table5
Dn(mm) |
AS |
L |
H |
H1 |
15 |
184 |
130 |
310 |
48 |
20 |
184 |
140 |
310 |
53 |
25 |
204 |
150 |
320 |
58 |
32 |
260 |
165 |
320 |
68 |
40 |
268 |
180 |
370 |
73 |
50 |
268 |
200 |
380 |
83 |
65 |
298 |
220 |
430 |
90 |
80 |
390 |
250 |
445 |
98 |
100 |
458 |
280 |
485 |
108 |
125 |
525 |
320 |
555 |
123 |
150 |
532 |
360 |
720 |
140 |
200 |
602 |
400 |
850 |
167 |
Notes: 1.Height dimension doesn't includehand wheel device
2.Falngedesign standards :JB/T79.1-94 or HG20592~20635-2009 or ANSI or JIS etc.
There is another forged C95800 ball valve fire safety design in Cowinns, thematerial anti-corrosion and widely used for sea water pipelines.